Esd Protection; Operating Conditions; Ground Concept - Safran LRF 6042 Manual

Table of Contents

Advertisement

LRF 6042 Integrator Manual

6.2 ESD protection

NOTICE
ESD (Electro Static Discharge) sensitive device. Permanent damage may occur on unconnected
devices subject to high energy electrostatic fields. Unused devices must be stored in conductive
foam or shunts. Personnel should be properly grounded prior to handling this device. The
protective foam should be discharged to the destination socket before devices are removed.
Parameter
All Lines

6.3 Operating conditions

Parameter
Operating Voltage PWR_IN
Operating Voltage PWR_SAFE
Typical values are recommended for operation.

6.4 Ground Concept

The LRF System has to be connected to the mechanical ground of the host system via the three screws and
the supportive conducting surface around them. The LRF bench is conductive and the contact surface shall
be conductive to avoid damages to the module.
INTEGRATOR MANUAL LRF 6042 917657- A
Confidential & Proprietary  SAFRAN VECTRONIX AG – All rights reserved
Typical
+2kV
+1kV
Note
Human body model (HBM)
Charged-device model (CDM)
Min
Typical
Max
8
12
42
3
5.0
5.25
Public: 02.2022
Page: 23/64
Unit
V
V

Advertisement