LRF 7047- Integrator Manual
6.5.2
Fake Range Request >LM,Mf,x*<CS><CR>
This command simulates a range measurement returning 3 or 5 constant targets.
A fake predefined value for the ranges as well as for the timestamps is returned.
Fake range request command and response
Command
Inputs
>LM,Mf,5*<CS><CR>
>LM,Mf,3*D7<0D>
Response
Outputs
>LM,Mf,range1,range2,range3*<CS><CR>
>LM,Mf,v0123400,v0432100,R000E301*57<0D>
Example of a successful Fake Range Request command transaction:
Host LRF Module
Command frame:
LRF Module Host
Acknowledge frame:
Response frame:
Prompt:
914929_TML_LRF7047_en_Version B
Confidential & Proprietary Safran Vectronix AG – All rights reserved
Description
Fake range request of x targets.
Example with x=3 targets.
Description
Response of LRF with parameter x=3
Example.
Table 4: Fake range request command
>LM,Mf,3*D7<0D>
>AC*84<0D>
>LM,Mf,v0123400,v0432100,R000E301*57<0D>
<
Public: 04.2019
Page: 43/72