Table of Contents

Advertisement

LRF 7047- Integrator Manual

Safety Notices

Integrator obligations
The information contained in this manual forms the basis for the safe use of the instrument. The person
responsible for the product must ensure that integrators are qualified and all users understand and
adhere to these instructions.
Always keep the instructions in direct access for users and any personnel working on the instrument.
WARNING
Risk of physical injury.
For safe use of the LRF module, please note the safety instructions below.
Keep this document for future reference.
Rangefinder
If the pointer is not active, the LRF7047 laser range finder emission is eye safe.
(According to EN 60825 and its amendments)
WARNING Laser Pointer
The LRF7047 (Article Number 913906) is a Class 3B Laser product because it contains a Class
3B laser pointer.
INVISIBLE LASER RADIATION
AVOID EXPOSURE TO BEAM
CLASS 3B LASER PRODUCT
Wavelength: 830 nm
Beam divergence: 0.45 mrad
Maximum Power: 180 mW
NOHD (Nominal Ocular Hazard Distance): 850 m (10 s)
NSHD (Nominal Skin Hazard Distance): 55 m (10 s)
In case of a broken fiber:
Nominal Ocular Hazard distance: 4.5 m (10 s)
Skin Hazard distance: 0.3 m (10 s)
WARNING
LRF 7047 is exclusively designed for use in OEM products. Use of controls or adjustments or
execution of procedures other than those specified herein may result in hazardous laser light
exposure. Do not open or modify any parts of the LRF module or attempt your own repairs. Do
not manipulate or adjust the performance of the LRF module.
914929_TML_LRF7047_en_Version B
Confidential & Proprietary  Safran Vectronix AG – All rights reserved
Public: 04.2019
Page: 2/72