LRF 7047- Integrator Manual
6.6.6
Reset LRF module to default settings >LM,Rd*<CS><CR>
This command resets all LRF module's configuration parameters to their default values.
An automatic restart of the LRF module is performed during the process.
Default parameters are:
Baud rate 57600
Range gate max 30000
Range gate min 00000
Timestamp deactivated
Reset LRF module settings command and response
Command
Inputs
>LM,Rd*<CS><CR>
>LM,Rd*7B<0D>
Response
Outputs
Example of a reset LRF module to default settings command transaction:
Host LRF Module
Command frame:
LRF Module Host
Acknowledge frame:
Prompt:
914929_TML_LRF7047_en_Version B
Confidential & Proprietary Safran Vectronix AG – All rights reserved
Description
Reset LRF module to default settings.
Example.
Description
No response expected.
Table 19: Reset LRF module settings command
>LM,Rd*7B<0D>
>AC*84<0D>
<
Public: 04.2019