Serial Interface; Rs232; Rs422; Pointer Interface: Interlock 1 To 4 - Safran LRF 7047 Manual

Table of Contents

Advertisement

LRF 7047- Integrator Manual

5.6 Serial Interface

5.6.1

RS232

The RS232 interface uses system connector pin#19 (RS232-TX) and pin#21 (RS232-RX) with the
following parameters:
Parameter
Baud rate
Data bits
Start bit(s)
Parity
Stop bit(s)
Signaling levels
Please see chapter 5.2 Pin descriptions for RS232/422 Interface selection with pin#18.
5.6.2

RS422

The RS422 interface uses system connector pin#17 (RS422-TX P), pin#19 (RS422-TX N), pin#21
(RS422-RX P) and pin#23 (RS422-RX N) with the following parameters:
Parameter
Baud rate
Data bits
Start bit(s)
Parity
Stop bit(s)
Signaling levels
Please see chapter 5.2 Pin descriptions for RS232/422 Interface selection with pin#18.

5.7 Pointer Interface: Interlock 1 to 4

To enable the non-eyesafe pointer, connect Interlock 1, 2, 3 and 4 together. If the Interlock pins are not
connected then there is no pointer emission possible. When the pins are connected, the corresponding
SW command (see chapter 6.5.4 and 6.5.5) can be sent to activate the pointer.

5.8 Ground Concept

The LRF System has to be connected to the host system ground via the three screws and the area
around the three screws. The LRF bench is conductive.