Eye Safety Kit; Deflection Area Of Double Stage Fiber Laser - Safran LRF 7047 Manual

Table of Contents

Advertisement

LRF 7047- Integrator Manual

4.8.1 Eye Safety Kit

The Eye Safety Kit is part of the Interface Kit (article number 914752) and includes screws, a filter that
reduces the pointer intensity and a protective plate to protect the fiber.
The Eye Safety Kit is intended to be used in laboratory conditions only. For full performance the filter has
to be removed. For more information on the filter, please contact Safran Vectronix AG.
Follow the follow steps below to mount the protective plate and the filter
1. Using a T6 screwdriver, attach the protective filter with two screws at position (A)
2. Remove protective cover screw (B) with a T6 screwdriver
3. Carefully place the large red protective plate over the fiber laser without damaging the fiber.
4. Secure the protective plate with the T6 screw from the Eye Safety Kit, using the screw hole at
position (B)

4.9 Deflection area of Double Stage Fiber Laser

NOTICE
The double stable fiber laser of LRF 7047 is equipped with shock absorbing elements to withstand pyro
shock impacts up to 800 g. These shock impacts can cause a deflection of the double stage fiber laser of
5 mm in X, Y and Z direction. To avoid damage to the LRF, do not place any other parts of the host
system in this area. See mechanical interface drawing in chapter 9.2 for more details.
914929_TML_LRF7047_en_Version B
Confidential & Proprietary  Safran Vectronix AG – All rights reserved
Figure 19: LRF 7047 with eye safety filter (red)
Public: 04.2019
Page: 30/72