Tightness check:
The tightness check is not essential and should be performed only by qualified personnel.
14
12
13
P_04346
20. Remove plugs (4 pieces) from the valves 12.
21. Open the compressed air supply.
22. Set blow-out air on pressure regulator 13 to 0 MPa; 0 bar; 0 psi.
23. Set piston air KV on pressure regulator 14 to 0.2 MPa; 2 bar; 29 psi.
24. Switch pump on by pressing the START/STOP button.
No air must leak!
25. Close compressed air supply again and depressurize system.
26. Replace plugs on the valves 12.