EDITION 08/2021

8.1.5 EXTERNAL CLEANING PROCEDURE

WARNING
Bursting powder hose!
Risk of injury and damage to the device.
The powder hose may be loaded with a maximum pressure of 0.6 MPa; 6 bar; 87 psi.
In this cleaning mode a separate cleaning box is used, and hoses and pump are blown
through with compressed air pulses from the suction hose.
Work steps:
1. End the coating procedure.
2. Switch DIP switch function 5 to "Off" (external cleaning with cleaning box,
order no. 241570), if necessary.
3. Disconnect suction hose from the feed unit and connect to the cleaning box.
Check hose coupling for secure fit!
4. Press the START/STOP button and empty pump and feed hose.
5. Disconnect feed hose and connect to the park station.
6. Press "Cleaning" button to start the cleaning procedure.
Note:
Depending on the powder type used, the cleaning procedure must be repeated
under circumstances!
7. Carefully blow out powder feeding parts (suction lance, surge damper, etc.) by hand.
8. Disconnect suction and feed hose from the cleaning box or park station and
reconnect to the relevant connection.
9. Restart the coating procedure.
ORDER NUMBER DOC241936
IP 5000
40