Safety instructions for the operator 2.1.1 Electrical equipment 2.1.2 Personnel qualifi cations 2.1.3 A safe work environment Safety instructions for staff 2.2.1 Safe handling of WAGNER spray units 2.2.2 Earth the unit 2.2.3 Material hoses 2.2.4 Cleaning 2.2.5 Handling hazardous liquids, varnishes and paints 2.2.6...
Page 4
Unica 4-270 EDITION 04 /2007 PART NO. ZZB006ENG OPERATING MANUAL Contents 5.1.6 Example of typical installation 5.1.7 Earthing Start up 5.2.1 Safety regulations 5.2.2 Pressure release procedure 5.2.3 Pump washing 5.2.4 Filling with working fl uid 5.2.5 Pump stop Finishing work and cleaning...
Unica 4-270 EDITION 04 /2007 PART NO. ZZB006ENG OPERATING MANUAL ABOUT THESE INSTRUCTIONS LANGUAGES ZZB006GER ZZB006ENG ZZB006FRE ZZB006ITA ZZB006SPA WARNINGS, NOTES AND SYMBOLS IN THESE INSTRUCTIONS...
Unica 4-270 EDITION 04 /2007 PART NO. ZZB006ENG OPERATING MANUAL GENERAL SAFETY INSTRUCTIONS SAFETY INSTRUCTIONS FOR THE OPERATOR 2.1.1 ELECTRICAL EQUIPMENT 2.1.2 PERSONNEL QUALIFICATIONS 2.1.3 A SAFE WORK ENVIRONMENT SAFETY INSTRUCTIONS FOR STAFF...
Unica 4-270 EDITION 04 /2007 PART NO. ZZB006ENG OPERATING MANUAL 2.2.1 SAFE HANDLING OF WAGNER SPRAY UNITS 2.2.2 EARTH THE UNIT 2.2.3 MATERIAL HOSES...
Technical data, Section 4.3.2 2.4.4 SAFETY REGULATIONS Safe handling of WAGNER spray units The maximum surface temperature of the pump can be reached if it runs dry. Ensure that the pump is filled with sufficient working or cleaning medium.
EDITION 04 /2007 PART NO. ZZB006ENG OPERATING MANUAL CE-CONFORMITY Herewith we declare that the supplied version of: Pneumatic pump with article no.: Mod. Unica 4-270 U580.00 Complies with the following provisons apllying to it: 98/37/CE 94/9/CE Atex-directives Applied standards, in particular:...
fl uid unit (Paragraph 4.3.1) is given. 4.1.2 EXAMPLES OF APPLICATION AREAS The main use of the Unica 4-270 pump is for transfering liquids inside the service circuit. Other typical applications are given below. Application Unica 4-270 ➚...
Unica 4-270 EDITION 04 /2007 PART NO. ZZB006ENG OPERATING MANUAL EXTENT OF DELIVERY Double-diaphragm pneumatic pump composed of: - Integrated pneumatic motor - Pumping stage CE-conformity see Chapter 3.3 Operating manual in english Part No.: ZZB006ENG Operating manual for the other language see Chapter 1.1...
OPERATING MANUAL 4.3.4 PERFORMANCE DIAGRAMS Example Stroke frequency DS/min 6 bar 4 bar 2 bar C_41_00003 Material fl ow volume water l/min <gpm> Diagram Unica 4-270 Stroke frequency DS/min bar (MPa) nl/min <psi> <scfm> 1000 30 (3) <35> <435> 22.5 (2.25) <26.5>...
Unica 4-270 EDITION 04 /2007 PART NO. ZZB006ENG OPERATING MANUAL WARNING Overpressure! Risk of injury from bursting components. Frequently check the safety valve efficiency by pulling the ring. C_SIHI_0026_GB Fluid section The fl uid section has been designed to work as a double-diaphragm pump with interchan- geable suction and delivery valves.
For information regarding the kit contents and assembling, please see the relevant para- graph in chapter 7 - Accessories. 5.1.2 PUMP INSTALLATION ON GROUND FRAME The Unica 4-270 pump installation kit on a ground frame can be supplied on request. Part number: Ground frame kit: T6148.00 For information regarding the kit contents and assembling, please see the relevant para- graph in chapter 7 - Accessories.
Install a pressure controller (C) on the pump regulating the pressure of the air entering the pneumatic motor and allowing to choose the desired running speed. The Unica 4-270 pump conveys the working fl uid a pressure of 4.5 times the supply air pressure, with peak pressure values of 30 bar.
Unica 4-270 EDITION 04 /2007 PART NO. ZZB006ENG OPERATING MANUAL 5.1.7 EARTHING Earthing schema (example per painting applications) Conveyor Workpiece Pump R max < 1 M Ω Spraying stand Paint container Anti-static fl oor C_41_00007...
Unica 4-270 EDITION 04 /2007 PART NO. ZZB006ENG OPERATING MANUAL START UP 5.2.1 SAFETY REGULATIONS Every time before starting up the following points should be observed as laid down in the operating instructions: - That it is possible to observe the safety regulations in Chap. 2.
Page 27
Unica 4-270 EDITION 04 /2007 PART NO. ZZB006ENG OPERATING MANUAL Before every start-up, the following points should be observed as laid down in the operating manual: - Check the permissible pressures - Check all connections for leaks - Check hose for damage It should be ensured that the unit is in the following state before carrying out any work on - Interrupt compressed air supply.
5.2.3 PUMP WASHING The Unica 4-270 pump is tested in the factory with oil. In case eventual testing fl uid residues may contaminate the working material, carry out a preliminary washing using a solvent compliant with the product. To perform the washing follow the instructions in the following paragraph, considering the solvent instead of the working material.
Unica 4-270 EDITION 04 /2007 PART NO. ZZB006ENG OPERATING MANUAL FINISHING WORK AND CLEANING Note The device should be cleaned for maintenance purposes, etc. Ensure that no remaining material dries and sticks. Procedure: 1. Follow the procedure foreseen to stop the pump -> chapter 5.2.5 2.
Unica 4-270 EDITION 04 /2007 PART NO. ZZB006ENG OPERATING MANUAL FAULT LOCATION, MAINTENANCE AND REPAIR TROUBLE SHOOTING AND SOLUTION Problem Cause Solution The pump does not • Air motor does not work or stops • Open and close ball valve on the pressure...
Page 31
IMPORTANT: In all cases where pump parts or pressurized pipes need to be disassembled, follow the pressure release procedure as described in Paragraph 5.2.2 before performing maintenan- If the problem is not listed above consult your WAGNER Service Center.
Unica 4-270 EDITION 04 /2007 PART NO. ZZB006ENG OPERATING MANUAL MAINTENANCE 6.2.1 LUBRICATION No lubrication is required for the pneumatic motor. An excessive lubrication may cause system failure. Regularly check the condition of compressed air fi lters mounted on the pneumatic motor pilot system (parts nr.
If lacking Wagner spare fl uid after carrying out the maintenance, it is possible to tempo- rarily fi ll the hydraulic circuit with water; however, it is advisable to replace it with Wagner working fl uid soonest possible. For further information please apply to a Wagner authori- sed engineer.
Page 34
Unica 4-270 EDITION 04 /2007 PART NO. ZZB006ENG OPERATING MANUAL Outlet valve Working fl uid...
WARNING: the best possible performance of the vacuum system inside the hydraulic circuit is important to guarantee the longest possible life of the membranes. The following opera- tions are hence to be carried out only by Wagner authorised engineers. 6.3.1.2 HYDRAULIC CIRCUIT EMPTYING Referring to the assemblying diagram in Paragraph 8.4:...