7.5.1 DIP SWITCH FUNCTIONS

Function No. Switch No.
1
1
2
2
3
4
5
5
6
7
8
9
10
11
The terms powder center or BigBag are synonymous for the distance of the pump to
the target tank.
Powder center distance < 20 m; 66 ft
BigBag distance > 20 m; 66 ft

7.5.2 A+/A- BUTTONS

With functions 2, 3, 4, 6, 7 and 9, the parameters can be adjusted with the A+/A- buttons
(see Chapter 6.9.3).
Note:
Only the parameters of the function currently set with the DIP switches can be changed.
ORDER NUMBER DOC241936
1
2
3
4
5
on
off
on
off
on
off
on
off
on
off
on
off
on
off
on
off
on
off
on
off
on
off
on
off
on
off
on
off
6
7
8 Explanation
1 on = use of powder center*
(hose lengths < 20 m)
1 off = use of BigBag*
(hose lengths > 20 m)
2 on = recipe "soft"
2 off = recipe "normal"
3+4 off = set after-run time
3 on
4 off = set cleaning time
5 on = internal cleaning
(without cleaning box)
5 off = external cleaning
(with cleaning box)
3 off
4 on = set service interval
3+4 on = set level controller time
6 on = standby deactivated
(from software version 1.03)
SuperCenter Cleaning Procedure
PXM Cleaning Procedure
For service purposes only, must be set to
"off"
IP 5000