8.4.2 ASSEMBLY
Work steps:
1. Screw in non-return valve (12) up to stop in bushing (11).
9
2. Mount non-return valve (9) with air connection (8) in control cabinet and screw
them loosely together.
3. Attach hose flange (6) to the pump body (1) and fasten with screws (7).
Do not damage the pump hoses!
ORDER NUMBER DOC241936
P_04335
11
8
12
P_04336
1
6
7
P_04337
IP 5000