13. Unscrew screws 8 on the upper and lower hose flange 9.
14. Remove hose flanges 9 at the top and bottom of the pump body 5.
15. Squeeze old pump hoses 10 lightly at the top and remove downwards from the
pump body 5.
16. Carefully introduce new pump hoses 11 (Chapter 8.3) into the pump body 5 from
the top.
Observe feed direction (arrow A)!
Do not damage the sealing surfaces!
ORDER NUMBER DOC241936
8
9
5
P_00010
5
10
P_00011
A
11
5
P_00012
IP 5000