EDITION 08/2021

7.5.8 SETTING EXAMPLE

100
90
80
The "Powder center" operating mode is activated in the example. 4 LEDs
70
light up on the display, which means that another 800 000 pump cycles
60
can be executed until the fault message appears
50
(factory setting 2 000 000 cycles - 800 000 possible cycles = 1 200 000 cycles
40
have been executed).
30
20
10
P_04310
100
90
80
70
60
After the display has changed to setting status, the LED lights up at value 50
50
(factory setting 2 000 000 with maximum 4 000 000 pump cycles).
40
30
20
10
P_04311
100
90
80
70
60
The setting value is increased to 2 400 000 cycles by pressing the A+ button.
50
40
30
20
10
P_04312
100
90
80
70
After exiting setting mode 5 LEDs light up, which means that another
60
1 200 000 cycles can be executed
50
(2 400 000 possible cycles - 1 200 000 completed cycles =
40
1 200 000 possible cycles).
30
20
10
P_04313