EDITION 08/2021
7.6
CYCLE COUNTER
The powder pump is equipped with a cycle counter, which triggers a warning signal
(fault LED flashes) after reaching a set number of pump cycles, prompting replacement of
the valve and pump hoses.
After replacing the pump and valve hoses, the cycle counter must be reset.
3
2
100
10
90
9
80
8
70
7
60
6
50
5
40
4
30
3
20
2
10
1
P_00036
Work steps:
1. Switch powder pump off with "ON/OFF" button 1.
2. Press buttons 2 and 3 simultaneously until the LED flashes quickly
(press button for at least 5 sec.).
The cycle counter is now reset, the LED bar is back to 100%.
7.7
CONDITIONS FOR OPERATING THE PUMP
No flushing is possible during the pump operation. Pressing the "Cleaning" button will
have no effect.
ORDER NUMBER DOC241936
1
Auto
IP 5000
IP 5000
38