5.5

DATA

5.5.1 TECHNICAL DATA

Dimensions:
Width
Height
Depth
Weight
Electrical:
Mains
Input power
IP Code
Ex zone
Pneumatic:
Input air pressure
Air consumption
Required compressed air quality Quality standard 6.5.2 according to ISO 8573.1, 2010
WARNING
Exhaust air containing oil!
Risk of poisoning if inhaled.
Insufficient paint application quality
The compressed air must meet the following quality requirements:
(Quality Standard 6.5.2 according to ISO 8573.1, 2010)
6.5.2 = particle density ≤ 5 mg/m³; pressure dew point ≤ +7 °C; oil content ≤ 0.1 mg/m³
Flow rate *
Maximum sound pressure level
Measurements according to DIN EN 3744
* Depending on suction length, feed length, feed height, powder level, adequately fast
running of the powder in the tank, powder composition.
Therefore, a 20-40% lower average flow rate can be assumed for the system design,
particularly for feeding from BigBags or boxes.
A residual quantity in the tank when changing is system-related and is not a malfunction.
Ambient conditions:
Operating temperature range
Maximum air humidity
ORDER NUMBER DOC241936
385 mm; 15.6 inch
760 mm; 29.92 inch
202 mm; 8 inches
approx. 20.5 kg; 45.2 lbs
24 VDC±20%
40 W
IP 54/IP 55
II 3D Ex tc IIIB T85°C Dc
0.6–0.8 MPa; 6–8 bar; 97–116 psi
10–24 m³/h; 353–874 cf
up to 5 kg/min depending on
operating mode and recipe
80 dB (A)
0–45 °C; 32–113 °F
80%