7.5.9 FUNCTION 7 "LEVEL CONTROLLER"

The level controller serves to guarantee a consistent filling level in the powder tank.
For this purpose an external level probe is connected, which sends the relevant signal to
the powder pump controller. When the level controller is switched on, the "Auto" display
flashes on the powder pump control panel.
Designation
1 Level sensor
2 Filling level according to level controller time
3 Minimum
Internal LED display
No LED lights up
LED 1 lights up
LED 2 lights up
LED 3 lights up
LED 4 lights up
LED 5 lights up
LED 6 lights up
LED 7 lights up
LED 8 illuminate
7.5.9.1 EXAMPLE FOR LEVEL SENSOR'S CONNECTION DIAGRAM
XST9
1
1
2
3
2
P_04315
Designation
1 Plug
2 Level sensor
ORDER NUMBER DOC241936
1
Function
Function deactivated (factory setting)
Signal 1 Pump on
Signal 0 Pump off (switch function)
Signal 1 Pump runs for 10 sec., if signal is subsequently still
present, pump runs for another 10 sec. until signal = 0
Same function as LED 2 with feed time of 30 sec.
Feed time 45 sec.
Feed time 60 sec.
Feed time 75 sec.
Feed time 90 sec.
Feed time 120 sec.
4
5
6
7
8
9
10
A1
11
A2
14
12
2
3
P_04314
PE
IP 5000
37