Function 1 "Use Of Powder Center/Bigbag; Function 2 Recipe "Soft; Function 3 "Set After-Run Time; Function 4 "Set Cleaning Time - WAGNER IP 5000 Translation Of The Original Operating Manual

Fresh powder and transfer pump
Hide thumbs Also See for IP 5000:
Table of Contents

Advertisement

EDITION 08/2021

7.5.3 FUNCTION 1 "USE OF POWDER CENTER/BIGBAG"

The setting to powder center or BigBag is dependent on the distance from the pump to
the target tank.
Note:
For rising heights above 3 m; 9.9 ft select the "BigBag" setting.

7.5.4 FUNCTION 2 RECIPE "SOFT"

This recipe is recommended for processing pressure-sensitive powder types.
The pump performance is reduced.

7.5.5 FUNCTION 3 "SET AFTER-RUN TIME"

If the pump stops, the inlet valves are closed and the pump body and feed hose are emptied.
This function is used for long hose lengths or warm ambient conditions
(risk of powder clumping).
With this function, the number of pump cycles can be set after switching off the pump.
The set number of pump cycles is displayed on the internal LED bar display
(see Chapter 6.9.3). No powder is drawn in during the after-run time.
0 LED lights up = function deactivated
1 LED lights up = 3 pump cycles
2 LEDs light up = 6 pump cycles
3 LEDs light up = 9 pump cycles
4 LEDs light up = 12 pump cycles
5 LEDs light up = 15 pump cycles
6 LEDs light up = 18 pump cycles
7 LEDs light up = 21 pump cycles
8 LEDs light up = 24 pump cycles

7.5.6 FUNCTION 4 "SET CLEANING TIME"

The adjusted cleaning time is shown on the display (see Chapter 5.3).
By pressing the A+/A- buttons the cleaning time is increased/ decreased.
Note:
Depending on the powder type used, the cleaning procedure must be repeated under
circumstances!
1 LED lights up = 15 cleaning cycles
2 LEDs light up = 16 cleaning cycles
3 LEDs light up = 17 cleaning cycles
4 LEDs light up = 18 cleaning cycles
5 LEDs light up = 19 cleaning cycles
6 LEDs light up = 20 cleaning cycles
7 LEDs light up = 21 cleaning cycles
8 LEDs light up = 22 cleaning cycles
9 LEDs light up = 23 cleaning cycles
10 LEDs light up = 24 cleaning cycles
ORDER NUMBER DOC241936
IP 5000
34

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ip 5000-usd

Table of Contents