Premium Delayed Egress
PED4000 D, PED5000 D Series Exit Device
Installation Instructions
18
Troubleshooting, continued
Refer to the following table and notes for an explanation of each LED's function.
Diagnostic LEDs
Yellow (Latch Bolt Status)
Red (Push Rail Switch)
Orange (Door Status Switch)
Green (Solenoid)
NOTES:
When the rail is armed (in Delayed Egress Mode) and the door is closed and latched, the Green Diagnostic LED should be ON
1.
only. All other LEDs should be OFF.
2.
With the rail armed, depressing the rail push bar slightly will turn the Red Diagnostic LED ON. The rail should go into alarm
immediately (no nuisance delay) or after being pressed for 1, 2, or 3-second nuisance delay setting. The rail will be in the
irreversible alarm mode and Cover LED is Amber with local audible beeping tone. After a standard delay of 15 seconds (or
30-second optional delay), the motor unblocks and passage is allowed. Cover LED is green (or red depending on DIP Switch
position 6 setting) with alarm at a steady tone which continues until reset by key switch.
3.
When a Door Status switch is used and the door is opened, the Orange Diagnostic LED will turn ON, which indicates that the
door is not closed. When not using a door status switch, DIP switch position 7 must be set to ON, Orange Diagnostic LED shall
be off.
YELLOW
RED
ORANGE
GREEN
For installation assistance contact Corbin Russwin
1-800-543-3658 • techsupport.corbinrusswin@assaabloy.com
Copyright © 2023 ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or in part without
the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
Function
ON - Latch bolt is retracted
OFF- Latch bolt is extended
ON- Rail Push Bar is depressed.
OFF- Rail Push Bar is released.
ON- Door Status Switch is open. Door is open/violated.
OFF- Door Status Switch is closed or DPS Bypass DIP switch position 6 is ON.
ON- Motor is in blocked/locked/armed postion.
OFF- Motor is in unblocked/disarmed position