Premium Delayed Egress
PED4000 D, PED5000 D Series Exit Device
Installation Instructions
13
Field Wiring Door Prep
NOTE:
•
Do not scale drawing.
•
Dimensions are in inches (") and millimeters (mm)
•
LHR H.M. opening shown. Details are typical for all opening materials (both hands).
•
This preparation is an addition to preparation shown on device template.
•
See device template to locate centerline.*
•
Shields for wiring access recommended for insulated and composite doors.
•
Locate and prepare wiring access holes when installing device.
Vertical
Reference
Horizontal
Reference
For installation assistance contact Corbin Russwin
1-800-543-3658 • techsupport.corbinrusswin@assaabloy.com
Copyright © 2023 ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or in part without
the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
Exit Device
ED4000 Series
ED5000 Series
Hinge Edge Detail
INSIDE FACE OF DOOR
Clear Channel Access
Required for Wire
Connection
1" (25mm) Dia.
(Wiring Access)
Horizontal Reference
Device Centerline
(See Note 5)
Exit Device End Clamp Mounting
Holes (For reference only)
32
Dim. A
1-11/16" (43mm)
2-5/16" (59mm)
Conducting Hinge or
Approved Power Transfer
(made by other manufacturers)
Rail
C L
Horizontal
of Push Rail
01.000
Metal: Thru inside wall only
Wood: 1 - 1/16" deep
5/8" Ref
(16mm)
5/16" Ref
(8mm)
1-1/4" Ref
(32mm)
A
Hinge Edge
Of Door
HINGE EDGE DETAIL
1/4"
Hinge
3/8"
Raceway
FM574 01/23