14-3/16
1/2
(13)
1-1/8
(29)
3
(76)
C L Hinge
Door Thickness
Step 1: Determine hand of door from illustration on upper right of this
page.
Step 2: Using template above locate and prepare holes in the frame &
door:
Frame
A. Prepare six (6) holes for 1/4-20 machine screws or
No. 14 x 2-3/4" (70mm) wood screws. Blind rivet nuts (by others)
are suggested for unreinforced hollow metal frames or for
aluminum frames.
B. Concealed Wired Units Only: Two (2) 7/8" (22mm) diameter
holes for conduit, for power input and for switch/sensor wires.
NOTE: On new construction these holes will generally be drilled
by the frame supplier at their shop or at the time the frame is
installed in the wall.
Door
C. Prepare three (3) holes for 3/8" diameter sex nuts. Standard units
Norton® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company.
Copyright © 2010, 2013 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
1. Hinge (Pull) Side Mounting Instructions
A
(360)
13-13/16
(350)
12-15/16
(329)
11-11/16
(297)
1-1/4
(32)
7/8 (23) Dia.
1-7/16
(2 Places)
(37)
11
(279)
Door Opening
Dim "A"
Angle
Up to 110°
15-1/2 (394)
111° to 180°
13-1/4 (337)
2" (51mm)
Min. Frame Face
1-3/4" (44mm) Min.
2-1/4" (57mm) Max.
1A. Installation Sequence
Right Hand Door
opening to 110° shown.
13-13/16
13-7/16
(341)
1/4-20 Machine Screws
or No. 14 Wood Screws
7-9/16
(192)
Please verify desired mounting
requires Hinge (Pull) Side
application as shown on this
template.
22
(559)
Notes:
• All dimensions are given in inches (mm).
• Thickness recommended for reinforcements in hollow
metal doors and frames is charted on Page 2.
• Do not scale drawing.
6" (152mm)
• Right hand door shown.
Min. Ceiling
• This template information based upon use of 5"
Clearance
(127mm) maximum width butt hinges. A separate
template is required for other conditions.
• Maximum frame reveal is 6-7/8" (175mm) for this
application.
• Conduit hole nearest the hinge is suggested for 120
VAC power input.
Frame
Note: Door must be visible by person
Reveal
operating activation switch(es)
are supplied with sex nuts and screws for 1-3/4" (44mm) thick door.
Sex nuts and screws for other door thicknesses are available to
order.
Step 3: Remove cover from the unit and set cover & cover screws aside.
Step 4: Mount unit to door frame. Select A or B below.
A. Concealed Wired Units Only:
backplate. Fasten unit to door frame (seven screws).
B. Surface Wired Units Only:
screws). Mount conduit bracket (found in screw pack) to unit's
backplate with two screws provided. Connect wiring conduit to
bracket.
Step 5: Mount track assembly to door using 3 1/4-20 screws & sex nuts
with buffer assembly toward hinge. Open part of track to face
top of door.
(Continue to next page.)
Page 4
ASSA ABLOY
(351)
(6 Places)
1-1/8"
(29)
3/8 Dia.
Sex Nuts
(3 Places)
Connect conduit to frame side of
Fasten unit to door frame (seven
80-9357-0001-020 (09-13)
6"
(152mm)
Min.
Clearance
2" (51mm)
Min.
Frame Face
5/8
Stop
(15.9)
Frame
Rabbet
Frame
Stop/Soffit

Advertisement