Premium Delayed Egress
PED4000 D, PED5000 D Series Exit Device
Installation Instructions
5
Wire Routing - continued
PED4800
Step 1 . Route wires as shown and secure trim to door .
Step 3 . Install rail .
For installation assistance contact Corbin Russwin
1-800-543-3658 • techsupport.corbinrusswin@assaabloy.com
Copyright © 2023 ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or in part without
the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
Electric Trim
(If applicable)
M93 Lever Monitoring
(if applicable)
M91 Connection
Step 4 . Make wire connections .
12
Step 2 . Route wires through chassis
as shown and secure chassis to door .
Step 5 . Pull back excess wire
through rail . Route wires as
shown . Install wire clips .