2
Insert and P.C. Board Assembly, continued
NOTES:
• Factory keyed orders will be shipped assembled.
• Prior to insert assembly, device must be cut to proper length to prevent damage to circuit board - 36" device cannot
be field cut. A maximum of 6" can be cut from a 48" device.
3

DIP Switch Settings

S2-1: Nuisance Audible may be selected ON (default) or OFF
S2-2 and S2-3: Nuisance Delay time may be selected 0 (Immediate),
S2-4 and S2-5: Reset Delay time may be selected 5, 10 (default), 20 or
S2-6: Cover Armed LED Color is Red (default) when ON and Green when OFF
S2-8: Switch must be set ON (default) to Bypass when an external
Door Position Switch (DPS) is NOT used, and OFF when an
S2 Dip Switch - Default Settings
S2 Dip SW
1
2
OFF (UP)
OFF
ON (DOWN)
ON
For installation assistance contact Corbin Russwin
1-800-543-3658 • techsupport.corbinrusswin@assaabloy.com
Copyright © 2023 ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or in part without
the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
1 (default), 2 or 3 seconds
S2-7: Re-arm After Closing (RAC)* (see below)
external DPS is used.
3
4
5
6
OFF
ON
ON
ON
40 seconds
PCBA DIP SWITCH VIEW
7*
8
OFF
ON
6
S2
1 Nuisance Audible
2 Nuisance Delay
3 Nuisance Delay
4 Reset Delay
5 Reset Delay
6 Armed LED Color
7 RAC
8 DPS Bypass