DIP Switch Settings

3
S2-1: Nuisance Audible may be selected ON (default) or OFF.
S2-2 and S2-3: Nuisance Delay time may be selected 0 (Im-
mediate), 1, 2, or 3 (default) seconds.
S2-4 and S2-5: Reset Delay time may be selected 5, 10 (de-
fault), 20 or 40 seconds.
S2-6: Whether an external LBM is used for not used for this
product, the switch must be set ON (default) to Bypass. S2-6
OFF position is not used.
S2-7: Switch must be set ON (default) to Bypass when an
external Door Position Switch (DPS) is NOT used, and OFF
when an external DPS is used.
Nuisance Delay (seconds)
S2-2
S2-3
Reset Delay (seconds)
S2-4
S2-5
* S2-8: When an external DPS is used and switch S2-8 ON, and 40 second reset delay (S2-4 and S2-5) are set
ON, after activation of momentary egress by cylinder key switch or external remote reset signal, if the Door/DPS
is open beyond 40sec the device will remain in momentary egress mode indefinitely and shall not enter alarm
mode; then once the Door/DPS is closed it will rearm immediately.
** With S2-8 OFF (S2-4 and S2-5 set for 5, 10, 20 or 40sec), if door/DPS is open after selected time the alarm will
sound. Close door to reset and rearm device using cylinder key or remote reset signal.
If door/DPS is opened then closed before selected time expires, the device will rearm immediately.
If DPS is not used, is bypassed with S2-7 ON, the door will rearm immediately after 5, 10, 20 or 40 sec whether
the door is open or closed, with either S2-8 ON or OFF.
Ensure eight S2 Dip Switches are set per application before moving on to the next page of instructions.
For installation assistance contact Corbin Russwin
1-800-543-3658 • techsupport.corbinrusswin@assaabloy.com
Copyright © 2006, 2010, 2018, 2020 ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
0
1
2
3
OFF
OFF ON
ON
OFF
ON
OFF
ON
5
10
20
40
OFF
OFF ON
ON
OFF
ON
OFF
ON
6
S2
Nuisance Audible
Nuisance Delay
Nuisance Delay
Reset Delay
Reset Delay
LBM Bypass
DPS Bypass
(Special) RAC
PCBA DIP SWITCH VIEW