Snood (Integrator) - Christie CP2230 Service Manual

Hide thumbs Also See for CP2230:
Table of Contents

Advertisement

5.9.4 Snood (Integrator)

The snood is located before the integrator and is removed when the Dolby
(Estimated Replacement Time: 2 minutes)
1. Remove the front top lid. Refer to
2. Remove the hex screw securing the snood. (Figure 5-26)
3. Remove the snood.
5.9.5 Integrator Assembly
(Estimated Replacement Time: 12 minutes + 15 minute calibration)
The integrator assembly is positioned on the IOS.
1. Remove the front top lid. Refer to
5-6.
2. Remove the two, 3mm hex screws securing the retaining clip
to the rear end of the integrator. (Figure 5-27)
NOTICE: Perform this step with caution to avoid damaging
the temperature sensor mounted nearby.
3. Remove the snood. Refer to
5-19.
4. Wearing the gloves provided with the Service Kit, carefully
remove the integrator assembly and set aside in a clean area
where it cannot be damaged.
5. When re-installing, repeat instructions in reverse. After
powering up the projector, adjust the integrator and fold mirror
as required for proper aperture alignment. For details, refer to
Section 3 Service
CP2230 Service Manual
020-100562-06 Rev. 1 (05-2016)
5.5.1 Front Top Lid, on page 5-6.
Wear the gloves provided in the Service Kit whenever handling the integrator.
5.5.1 Front Top Lid, on page
5.9.4 Snood (Integrator), on page
Setups.
Section 5: Parts and Module Replacement
filter wheel is used.
®
Figure 5-26 Screw
Securing Snood
Figure 5-27 Integrator Assembly
5-19