80
5
. Go to printer driver setup window (see
Section 7-D) by selecting Page Setup from the
File menu. Click on the Expert button and then
on the CalÉ button of the Expert Options dialog
box. The printerÕs ribbon sensor calibration
window appears (see also Section 7-D for more
information on the ribbon sensor calibration
window).
6
. Click on the appropriate Send button to
download the proper ribbon sensor calibration
sequence for the ribbon you currently have
installed in your printer.
Select SEND Wax Ribbon Test to adjust the
ribbon sensor if you have a resin thermal or wax
thermal transfer ribbon installed.
Select SEND 9Ó Dye Ribbon Test to adjust the
ribbon sensor if you have the A/A4-Super (9Ó x
14Ó) dye-sublimation ribbon installed.
Select SEND 12Ó Dye Ribbon Test to adjust the
ribbon sensor if you have the B/A3-Super (12Ó x
20Ó) dye-sublimation ribbon installed.
7
. After the data is sent, you will hear the
printer cycle the printhead. Then, the printerÕs
cancel LED light or on-line LED light will flash.
This indicates that the ribbon sensor is in need of
adjustment.
8
. To adjust the ribbon sensor, locate the four
small holes toward the bottom of the printerÕs
metal chassis. Each of these holes has a specific
function. Hole #1 adjusts the overall
lightness/darkness of the printed page and
should NOT be adjusted. Hole #2 recalibrates
the ribbon sensor for the resin thermal and wax
thermal ribbons. Hole #3 recalibrates the ribbon
sensor for the A/A4-Super size (9Ó x 14Ó) dye-