Hold the sensor only by its connector. Touching the sensor may change the resistance value.
When measuring, the sensor temperature must be the same as the ambient temperature.
HINT:
As the temperature increases, the resistance decreases (see the graph).
Text in Illustration
Component without harness connected
*1
(Room Temperature Sensor)
*2
Sensing Portion
NG
REPLACE ROOM TEMPERATURE SENSOR
OK
3.
CHECK HARNESS AND CONNECTOR (ROOM TEMPERATURE SENSOR - A/C AMPLIFIER)
2010 Toyota Prius
(a) Disconnect the A/C amplifier connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
L17-29 (TR) - L44-1
L17-34 (SG-1) - L44-2
L17-29 (TR) - Body ground
L17-34 (SG-1) - Body ground
Text in Illustration
Condition Specified Condition
Always
Below 1 Ω
Always
Below 1 Ω
Always
10 kΩ or higher
Always
10 kΩ or higher