OPERATION CHECK
1. SOLAR VENTILATION SYSTEM OPERATION CHECK
(a) Inspection of Voltage Generated by Moon Roof Glass Assembly (Solar Panel)
(1) Park the vehicle in a location with a stable temperature and a sufficient amount of sunlight, and leave the
vehicle as is for approximately 10 minutes.
NOTICE:
To ensure stable generation of voltage by the moon roof glass assembly (solar panel), make sure to park the
vehicle in a location where the system operation conditions reference table are satisfied.
HINT:
The solar ventilation system operates only when the generated voltage is 10 V or higher. Therefore, make sure
to park the vehicle where the system operation conditions reference table are satisfied. This will allow the moon
roof glass assembly (solar panel) to generate a voltage of 10 V or higher.
System Operation Conditions Reference Table
Item
Amount of sunlight
Moon roof glass assembly (solar
panel) status
Ambient temperature
(2) Connect the Techstream to the DLC3.
(3) Turn the power switch on (IG).
(4) Turn the Techstream on.
(5) Enter the following menus: Body Electrical / Air Conditioner / Data List.
Air Conditioner
Tester
Display
Solar panel voltage /
Solar
Variable, 10V les, 10V-11V, 11V-12V, 12V-13V, 13V-
Voltage
14V, 14V-15V, 15V-16V, 16V-17V, 17V-18V, 18V-
19V, 19V-20V, 20V-21V, 21V-22V, 22V-23V or 23V
2010 Toyota Prius
A sufficient amount of sunlight is received by the moon roof glass assembly
(solar panel).
(The amount of sunlight on a cloudless day between 11:00 and 14:00 is
typically sufficient for operation.)
The moon roof glass assembly (solar panel) is not in the shade
No fallen leaves or dirt is present on the moon roof glass assembly (solar
panel)
20 to 40°C (68 to 104°F)
Measurement Item/Range
Condition
Normal
Condition
System operation
Actual generated
conditions reference
voltage
displayed
table are met
Diagnostic Note
.
Repair Manual