92 Installation and configuration
To configure new Host SDI maintenance and service change, load
Configuration Record Program LD 17 and Configuration Record Program
LD 97.
To enable the superloop, load Maintenance and Diagnostic Program LD 32
and execute the ENLL sl command.
Copyright © 2007-2009 Nortel Networks
.
Table 20
To define a carrier superloop
Prompt
Response
REQ
CHG
TYPE
SUPL
SUPL
0–156
SLOT
(L) R
XPEC
1–95
Table 21
Configuring the SDI port for the Superloop Network card connection
(LD 17)
REQ
CHG
TYPE
CFN
IOTB
YES
HIST
ADAN
NEW TTY
0–15
USER
BUG MTC
SCH
XSM
(NO)
Table 22
To enable the superloop sl
Command
Response
ENLL sl
OK = op
eration is
successful.
Nortel Communication Server 1000
Fiber Remote Multi-IPE Interface Fundamentals
NN43021-556 03.01
11 May 2009
Description
Adding a new Superloop Network card
Adding a superloop for the Superloop Network
card.
Superloop number
Superloop card side for the Superloop Network
card, where L (left) is default position.
Peripheral Controller card previously equipped.
Change the SDI record
Configuration record
I/O terminal history file buffer length
Add, change, or remove an I/O device, type aaa,
or port x
Enter one of the output message types that will
be the message of this port
SDI port for the system monitor
Comment
Enables specified superloop sl