Nortel Communication Server 1000 Series Manual page 70

Fiber remote multi-ipe interface fundamentals
Table of Contents

Advertisement

70 Installation and configuration
Connecting the external alarm cable at the local site
The Fiber Remote Multi-IPE Interface unit provides an external alarm
output connector (ALM), which is connected to external alarm indicators at
the local site. These alarm outputs indicate external alarm contact closures
at the Remote IPE site and the failure of the fiber-optic link.
Use a cable with a DB-9 male connector at one end and open wires at
the other end. The open-wire end can be customized with connector(s)
to match your external alarm indicator devices. The length of the cable
depends on the distance between the Fiber Remote Multi-IPE Interface
unit and the external alarm devices.
Table 11 "The DB-9 female ALM connector pinouts (local site)" (page
70)
connector pinouts for each external output alarm indicator.
Table 11
The DB-9 female ALM connector pinouts (local site)
External Alarm
Output Contact Closure
Output alarm #1 (activated by remote external
alarm #1)
Output alarm #2 (activated by remote external
alarm #2)
Output alarm #3 (activated by a fault in the
fiber-optic link)
Output alarm return
To install the external alarm cable, follow the steps in
"Connecting the external alarm cable at the local site" (page
Procedure 17
Connecting the external alarm cable at the local site
Step
1
2
Copyright © 2007-2009 Nortel Networks
.
lists the Fiber Remote Multi-IPE Interface unit DB-9 female ALM
Action
Plug the cable DB-9 male connector into the DB-9 female ALM
connector on the Fiber Remote Multi-IPE Interface unit.
This cable is not supplied.
Connect the other end of the cable to the external alarm indicator
devices. Observe the wire color codes and their corresponding
pin assignments at the connector when wiring the external alarm
devices to the cable.
Nortel Communication Server 1000
Fiber Remote Multi-IPE Interface Fundamentals
NN43021-556 03.01
11 May 2009
Connector Pin
7
2
6
1
Procedure 17
--End--