54 Installation and configuration
Setting the S2 dip-switch
Dip-switch S2 defines the physical location of the Fiber Remote Multi-IPE
Interface unit in the fiber-optic link.
To specify the physical location of the Fiber Remote Multi-IPE Interface
units, follow the steps in
Procedure 4
Setting the S2 dip-switch
Step
1
2
Installing redundant fiber-optic link option
The redundant fiber-optic link is optional. Unless the system configuration
requires a redundant fiber-optic link, it is not necessary to install the
following hardware.
To install the redundant fiber-optic link connectors, install the
daughterboard that corresponds to the type of fiber used in the link. Refer
to
Figure 7 "Installing the redundant fiber-optic link option" (page 56)
installation details.
Copyright © 2007-2009 Nortel Networks
.
S1 position 1 to OFF and position 2 to ON, as shown in
9 "Fiber Remote Multi-IPE Interface configuration" (page
Note: To assign a unique address to each Fiber Remote
Multi-IPE Interface in a daisy-chain at the local site, set S1
positions 3-8 as shown in
Interface and system monitor address selection table" (page
50). At the Remote IPE site, use this table to assign a
unique system monitor address of the Fiber Remote Multi-IPE
Interface, which is connected to the system monitor card in
the pedestal of the Remote IPE column. The system monitor
address must be the same as the address of the Fiber Remote
Multi-IPE Interface connected to the system monitor card in
the pedestal.
Procedure 4 "Setting the S2 dip-switch" (page
Action
For the local Fiber Remote Multi-IPE Interface units, set
dip-switch S2 position 1 to OFF.
For the remote Fiber Remote Multi-IPE Interface units, set
dip-switch S2 position 1 to ON, as shown in
Remote Multi-IPE Interface configuration" (page
Nortel Communication Server 1000
Fiber Remote Multi-IPE Interface Fundamentals
NN43021-556 03.01
11 May 2009
Table 10 "Fiber Remote Multi-IPE
--End--