Setting S1 and S2 switches at the local site
Before installing a Fiber Remote Multi-IPE Interface unit:
Table 9 "Fiber Remote Multi-IPE Interface configuration" (page 49)
functions controlled by dip-switches S1 and S2. It also shows how to set
these switches to configure the Fiber Remote Multi-IPE Interface.
Table 9
Fiber Remote Multi-IPE Interface configuration
For single Fiber Remote Multi-IPE
Fiber Remote Multi-IPE Interface at
the SDI port end of the daisy-chain
Fiber Remote Multi-IPE Interface in
Table 10 "Fiber Remote Multi-IPE Interface and system monitor address
selection table" (page 50)
Remote Multi-IPE Interface unit in a daisy-chain and the system monitor
address. Each Fiber Remote Multi-IPE Interface must have a unique
address from 0 to 63.
Copyright © 2007-2009 Nortel Networks
.
configure the Fiber Remote Multi-IPE Interface using S1 and S2
dip-switches
install redundant fiber-optic connectors, if required
Function selection
Interface unit
Fiber Remote Multi-IPE Interface
at the MMI terminal or modem
end of the daisy-chain
the middle of the daisy-chain
Fiber Remote Multi-IPE Interface
address in a daisy-chain and
system monitor address
Physical location of the Fiber
Remote Multi-IPE Interface
Reserved for future use
Note: Switch position: ON= Up and OFF= Down for S1 and S2 switches.
Nortel Communication Server 1000
Fiber Remote Multi-IPE Interface Fundamentals
NN43021-556 03.01
11 May 2009
Fiber-optic equipment installation 49
Switch and
Position
S1 Position 1
and Position 2
S1 Position 1
Position 2
S1 Position 1
Position 2
S1 Position 1
Position 2
S1 Positions
3–8
S2 Position 1
S2 Positions 3–8
lists the available addresses for each Fiber
lists
Switch setting
ON (at local and
remote sites)
ON
OFF
OFF
ON
OFF
OFF
Refer to
Table 10
"Fiber Remote
Multi-IPE
Interface and
system monitor
address selection
table" (page 50)
ON-Remote site
OFF-Local site
OFF