To configure the S1 dip-switch, refer to
fiber-optic link option" (page 56)
"Setting the S1 dip-switch" (page
Procedure 3
Setting the S1 dip-switch
Step
1
2
Copyright © 2007-2009 Nortel Networks
.
Action
Eject the motherboard from the metal enclosure by pushing the
ejector tabs outward away from the Fiber Remote Multi-IPE
Interface faceplate.
Configure the Fiber Remote Multi-IPE Interface using the S1
dip-switch.
Refer to
Table 9 "Fiber Remote Multi-IPE Interface configuration"
(page 49)
and
Table 10 "Fiber Remote Multi-IPE Interface
and system monitor address selection table" (page 50)
instructions.
•
For a single unit. If the Fiber Remote Multi-IPE Interface
units are not daisy-chained, set dip-switch S1 positions 1 and
2 to ON.
•
First unit in the chain. For the first Fiber Remote Multi-IPE
Interface in the daisy-chain, the SDI connector connects to
the MAINT connector of the following Fiber Remote Multi-IPE
Interface and its MAINT connector connects to the MMI
terminal through the MMI Adapter. Set dip-switch S1 position
1 to ON and position 2 to OFF, as shown in
Remote Multi-IPE Interface configuration" (page
•
Unit in the middle of the chain. For Fiber Remote Multi-IPE
Interface units in the middle of the daisy-chain, set dip-switch
S1 position 1 and 2 to OFF.
•
Last unit in a daisy-chain. For the Fiber Remote Multi-IPE
Interface at the end of the daisy-chain, the SDI connector
connects to the SDI port in the local system and the MAINT
connector connects to the SDI connector on the next Fiber
Remote Multi-IPE Interface in the daisy-chain. Set dip-switch
Nortel Communication Server 1000
Fiber Remote Multi-IPE Interface Fundamentals
NN43021-556 03.01
11 May 2009
Fiber-optic equipment installation 53
Figure 7 "Installing the redundant
and follow the steps in
53).
Procedure 3
for
Table 9 "Fiber
49).