Nortel Communication Server 1000 Series Manual page 122

Fiber remote multi-ipe interface fundamentals
Table of Contents

Advertisement

122 Remote IPE maintenance
Table 28
MMI commands (cont'd.)
Command
D S [P]
D S D
H or ?
HOST or HO
L
L xx
Q
S A
S C
S D
S L
S N
S T
T A
T FI
Copyright © 2007-2009 Nortel Networks
.
Description
Display status [Pause]. Displays near-end superloop
and fiber-optic link status.
Display status distant. Displays far-end superloop and
fiber-optic link status.
Help. Displays the Help screen.
Connects the MMI terminal to the SDI port. The
password is HOST.
Logs in to the MMI terminal for one Fiber Remote
Multi-IPE Interface. The password is FIBER.
Logs in to a specific superloop when the system
has more than one Fiber Remote Multi-IPE Interface
connected in a daisy-chain, where xx is the Fiber
Remote Multi-IPE Interface address in the chain. The
password is also FIBER.
Logs the terminal user out.
Sets the fiber-optic link bit errors per minute alarm
threshold in the range from 10-10 to 10-6.
Sets alarm self-clearing function to either "enable" or
"disable".
Sets date or verifies current date.
Set link. Configures which fiber-optic link (A or B) is
selected to transmit data, for a redundant link.
Set name. Sets the name for the site and superloops.
The site name can be 9 characters long and the
superloop name can be 5 characters long. These
names are shown in the Display Status screen.
Sets time or verifies current time.
Test all. Initiates a series of pre-programmed tests on
the near-end and far-end superloops and fiber-optic
links.
Test duration can be set from 1 to 98 minutes. By
entering 0, the tests run one time. To stop testing enter
STOP.
Test fiber. Initiates a series of pre-programmed tests
on the fiber-optic links. Test duration can be set from 1
to 98 minutes. By entering 0, the tests run one time.
To stop testing enter STOP.
Nortel Communication Server 1000
Fiber Remote Multi-IPE Interface Fundamentals
NN43021-556 03.01
11 May 2009

Advertisement

Table of Contents
loading

This manual is also suitable for:

Communication server 1000e cp piiCommunication server 1000e cp pivCommunication server 1000e cp pmCommunication server 1000m single group cp piiCommunication server 1000m single group cp pivCommunication server 1000m multi group cp pii ... Show all

Table of Contents