OPERATION
If the display shows "Ent": You must enter your password
using the UP and DOWN buttons. When your password
*
is displayed, press the
/FUNC button to test the
password. If the password is correct, you will be able to
change the acre counter settings. The password will be
viewable until the acre counter enters sleep mode. When
the acre counter is in entry mode again, you will have to
re-enter the password to change settings.
If the password is not correct, you will not be able to
change the acre counter settings. When the "PASS"
function is selected again, "Ent" will appear in the
display.
Changing the Password
Select a new password using the UP and DOWN
*
buttons. Press the
/FUNC button until the word "SEt"
*
appears in the display. Release the
/FUNC button. The
number in the display is your new pass code. Make sure
*
you record this number. Press and hold the
/FUNC
button until the word "dIS" appears in the display.
If the password is forgotten, it can be disabled by
removing the batteries. The password is intended for
rental units. It is recommended that a seal be affixed to
the rear plate of the acre counter to determine if the
settings have been tampered with.
Battery Replacement
The battery operated acre counter uses 3 AA batteries.
The "BATT" LED will light when the batteries require
replacement. Remove the acre counter from the
implement and undo the 4 screws on the back of the
case. See Figure 3-30. This will separate the housing
from the rear plate. Replace the batteries with 3 high
quality AA alkaline batteries.
See "Acre Meter Troubleshooting" on page 5-10.
Acre Meter
Remove screws
to replace batteries
Figure 3-30: Battery Replacement