Download Print this page

Landoll Brilllion Till'N Seed BPSB-8 Operator's Manual page 43

Advertisement

Large Meter Box Calibration
for Unlisted Seeds
NOTE
Calibration Crank Assembly used for Calibration is stored
in the toolbox.
Brillion assumes no liability pertaining to Seeding Rates
achieved with this Seeder. Rates listed are general in
nature and should be used as starting points only. Seed
varieties and blends listed represent those calibrated
through in-house test meters.
Variations in actual rates may be realized due to
differences in seed lots. For accurate rates with seeds
being used, follow the calibration instructions listed on the
Seed Chart inside the Seed Box Cover or refer to this
Manual. See Figure 3-21. The information listed in the
Seed Chart is subject to change without notice.
Calibrate Unlisted Seeds as follows:
1. Seed Shaft turns 337 revolutions per acre seeded in
low range. Seed Shaft turns 517 revolutions per acre
seeded in high range.
2. Raise machine and lock in Transport Position.
3. Place Calibration Tray in collection position to catch
seed. Remove the 5/16-18 Wing Nuts that secure the
Calibration Tray Cover over the opening in the RH
Support Plate. See Figure 3-15. Remove the 5/16-18
Wing Nut that secures the Calibration Tray in the
Storage position. Orient the Calibration Tray with
Handle to the top and insert it into the RH Support
opening. See Figure 3-16.
4. Remove Large Meter Drive Pin. See Figure 3-20.
5. Turn transmission Large Meter Shaft Calibration Hex
337 revolutions clockwise (CW) for low range or
517 revolutions clockwise (CW) for high range with
provided crank. 56 low range or 86 high range turns
may be used if results are adjusted as stated in Step 6.
6. Weigh seed for approximate planting rate in lbs/acre.
Multiply weight by 6 if only 56 low range or 86 high
range turns were used.
7. Install Large Meter Drive Pin.
8. Place Calibration Tray back in storage position. See
Figure 3-18. Re-install Calibration Opening Cover
over the opening in the RH Support Plate with 5/16-18
Wing Nuts.
F-1097-2305
TABLE OF CONTENTS
15 Tooth
High Range
23 Tooth
Low Range
Figure 3-20: Large Meter Box Calibration
OPERATION
Micro-Meter
Calibration Hex
19 Tooth
Agitator
Shaft
Large Meter
Drive Pin
218254
Calibration
Crank
3-11

Advertisement

loading