AT commands

CC (Command Sequence Character)

Sets or reads the character the device uses between guard times of the AT Command mode
sequence. The AT Command mode sequence causes the device to enter Command Mode (from Idle
Mode).
Note
We recommend using the a value within the rage of 0x20-0x7F as those are ASCII characters.
Parameter range
0 - 0xFF
Default
0x2B (ASCII + character)

CT (Command Mode Timeout)

Sets or reads the Command mode timeout parameter. If a device does not receive any valid
commands within this time period, it returns to Idle mode from Command mode.
Parameter range
2 - 0x1770 (x 100 ms)
Default
0x64 (10 seconds)

CN (Exit Command mode)

Makes the device exit Command mode.
Immediately exits Command Mode.
Parameter range
N/A
Default
N/A

GT (Guard Times)

Set the required period of silence before and after the command sequence characters of the
Command mode sequence (GT + CC + GT). The period of silence prevents inadvertently entering
Command mode.
Parameter range
0x2 - 0x95C (x 1 ms)
Default
0x3E8 (one second)