Commands
Bytes returned
2
BT (Guard Time Before)
Sets the DI pin silence time that must precede the Command Sequence Character (CC command) of
the Command mode sequence.
Binary command
0x04 (4 decimal)
Parameter range
0 - 0x1770 [x 100ms]
Default
0x0A (1 second)
Bytes returned
2
CC (Command Sequence Character)
Sets or displays the character the device uses between guard times of the AT Command mode
sequence. The AT Command mode sequence causes the device to enter Command Mode (from Idle
Mode).
Binary command
0x13 (19 decimal)
Parameter range
0x20 - 0x7F
Default
0x2B (ASCII "+")
Bytes returned
1
CF (Number Base)
Sets or displays the command formatting setting.
The firmware always enters and reads the following commands in hex, no matter what the CF setting
is:
VR (Firmware Version)
HV (Hardware Version)
KY (AES Encryption Key)
Binary command
N/A
XBee®/XBee-PRO XTend Compatible (XTC) RF Module User Guide