Barco FSN-1004 User Manual page 173

Table of Contents

Advertisement

4.
5.
6.
7.
8.
9.
10.
Processing Setup
parameters:
1.
2.
3.
4.
Sizing and Scaling
1.
2.
3.
FSN-1004 • User's Guide • Rev 00
updated. Once the system acquires a new format, it automatically scales
the input up (or down) to the current native resolution.
Note
If an exact match cannot be found, you may need to use
{Input Format} button to set the format manually.
If required, press {Input Format} to display the Input Format Keypad . Locate
the desired format and press {Apply} .
Analog and DVI inputs only
Format Keypad . Locate the EDID format and press {Apply} to program EDID.
Important
This function is designed for advanced users only. Do not
program the EDID unless it is necessary.
Analog and DVI inputs only
and RGB processing, as required.
Analog inputs only
— Press {1:1 Sampling} to toggle the 1:1 sampling mode on
or off, as required.
Analog inputs only
— Press {Sample Phase} , and use the Sample Phase
control to adjust the input's A/D converter. For optimum visual results when
adjusting high-resolution sources, output a burst test pattern from the source, and
adjust for minimum noise.
Analog inputs only
— Press {Adjust H Timing} to adjust the image's horizontal
timing. Use the {H Pos} , {H Active} and {H Total} controls as required.
Analog inputs only
— Press {Adjust V Timing} to adjust the image's vertical
timing. Use the {V Pos} and {V Active} controls as required.
— Use the following steps to set up universal input processing
Press {Sharpness} , and use the Sharpness control to set the input's sharpness.
Component, S-video and composite inputs only
to toggle the Pulldown Compensation mode on or off, as required.
Interlaced formats only
— Press {De-Interlace} to display the De-Interlace
Pop-up . Choose either Motion Adaptive or Field to Frame mode.
If Motion Adaptive de-interlacing is selected, press {Motion Threshold} and use
the control to adjust the threshold of the motion adaptive de-interlacer, if required.
— Use the following steps to set up sizing and scaling:
Press {Sizing and Scaling} to display the Sizing and Scaling Panel .
Use the {Mask Top} , {Mask Bottom} , {Mask Left} and {Mask Right} controls to
mask selected portions of the image, as required.
Select the method by which you want to size and scale the image. Masked edges
are taken into account.
~
Press {Fill H} to scale the selected universal input up (or down) to the
current native horizontal resolution. Aspect ratio is maintained.
~
Press {Fill V} to scale the input up (or down) to the current native
vertical resolution. Aspect ratio is maintained.
~
Press {Fill H/V} to scale the input up (or down) to the current native
horizontal and vertical resolutions. Aspect ratio is not maintained.
— Press {EDID Format} to display the EDID
— Press {Color Space} to toggle between SMPTE
— Press {Pulldown Comp}
5. System Setup
Universal Input Setup
173

Advertisement

Table of Contents
loading

Table of Contents