Installing the M.2 NVMe SSD on the system board

Installing the M.2 NVMe SSD on the system board
NVMe SSDs are directly attached to the PCIe interface and do not have a dedicated hardware RAID engine similar to SAS controllers.
This means that RAID configuration for NVMe SSDs is only supported through the operating system.
IMPORTANT:
IMPORTANT:
When installing HPE 400 GB NVMe x4 MU M.2 22110 DS SSD (875583-B21) and HPE 480 GB NVMe x4 RI M.2 22110
DS SSD (875579-001) modules, the supporting ambient temperature should be under 30°C (86°F).
Prerequisites
Prerequisites
Before you perform this procedure, make sure that you have the following tools available:
T-15 Torx screwdriver
4.5 mm hex nut screwdriver
Phillips No. 1 screwdriver
Procedure
Procedure
1. If installed, remove the front bezel .
2. Power down the server.
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4. Disconnect all peripheral cables from the server.
5. Remove the server from the rack .
6. Remove the access panel .
7. If an expansion board is installed in the riser board slot 1, remove the riser cage.
8. Remove the M.2 air guider.
9. Identify the M.2 SSD type to be installed, and then locate the standoff position corresponding to that type .
10. Do one of the following:
For M.2 2242 or 2280 SSD installation, remove the hex nut and Phillips screw.
Installing the M.2 NVMe SSD on the system board