Operating manual GA 5000EAC Electrostatic Automatic Spray Gun (AirCoat)
7   Operation
7. Before tightening with the air cap horns (Y), set the desired jet level and then tighten
the union nut to stop by hand.
7.11   CLEANING OF THE NOZZLE PARTS
The nozzle parts may only be immersed in a cleaning solvent recommended by the lacquer
manufacturer and must be removed again immediately. They may only remain in a cleaning
solvent for a short time.
Clean these parts with a brush and dry them with a cloth or a blow gun.
7.12   ELIMINATING NOZZLE CLOGGING
Y
Y
9
A
B
A
ACF5000 nozzle in spray position
1. Switch control unit to standby operation.
2. Unscrew union nut completely (12) and remove air cap (10).
3. Push ACF 5000 nozzle (11) out of air cap (10) by hand, reverse it and put it into the air
cap (10) with the nozzle tip towards the rear. Pay attention to the position of the guide
surfaces (X).
4. Insert air cap (10) with integrated ACF 5000 nozzle (11) into the union nut (9). Make sure
that the air cap horns (Y) lie in the recess of the nozzle guard.
Order number 2360922 | Edition 09/2022
X
11
10
B
1
B_05774
ACF5000 nozzle in cleaning position
12
12