Operating manual GA 5000EAC Electrostatic Automatic Spray Gun (AirCoat)
3   Identification
3   IDENTIFICATION
3.1   EXPLOSION PROTECTION IDENTIFICATION
As defined in the Directive 2014/34/EU (ATEX), the device is suitable for use in potentially
explosive areas.
Device Type
Manufacturer
 
 II 2 G 0.24 mJ
0102
SIRA 16 ATEX 5290 X
CE
0102
Ex
II
2
G
0.24 mJ
SIRA 16 ATEX 5290 X
Temperature notes
– Maximum surface temperature: 85  °C; 185  °F
– Maximum permissible product temperature: 50  °C; 122  °F
– Permissible ambient temperature: 0 to +40  °C; +32 to +104  °F
3.2   IDENTIFICATION "X"
Notice: SIRA 16 ATEX 5290 X
The EU Type Examination Certificate covers the following:
– The use of the spray gun in Zone 1
– The use of the EPG 5000 control unit as related equipment for the spray gun.
Cable connections
Only cables assigned to the device may be used (see chapter Accessories [8 69]).
Permissible device combinations
The GA 5000EAC automatic spray gun may only be connected to the control units listed
below:
– EPG 5000
Order number 2360922 | Edition 09/2022
Electrostatic automatic spray gun GA 5000EAC
Wagner International AG
9450 Altstätten
Switzerland
European Communities
Notified body: PTB
Explosion-proof equipment
Device group II (not mining)
Category 2 device (suitable for zone 1)
Ex-atmosphere gas
Maximum ignition energy
Number of type examination certificate
"X": see chapter Identification "X" [8 11].