7   Operation
5. Screw complete preassembled union nut (12) to gun (1) and tighten by hand.
6. Switch on gun without high voltage and flush gun.
7. When the blockage has been flushed out, switch control unit back to standby
operation.
8. Unscrew union nut (12) completely.
9. Remove air cap (10) and push ACF 5000 nozzle (11) out of the air cap by hand. Clean
ACF 5000 nozzle and in the spraying position, insert it back into the valve housing.
10. Put the air cap (10) on the nozzle (11) and pay attention to the position of the guide
surfaces (X).
11. Screw union nut with attached nozzle guard (9) to the gun body and make sure that the
air cap horns lie in the designated recess (Y).
12. Before tightening with the air cap horns (Y), set the desired jet level and then tighten
the union nut to stop by hand.
13. Switch control unit to the required operating mode.
7.13   CHANGING THE VALVE HOUSING
ü Pressure was relieved (see chapter Pressure Relief / Work Interruption [8 41]).
4 Use a socket or ring wrench (not a combination wrench) to tighten the valve housing.
SW9
1.8 Nm
1.32 lb ft
48
B_06426
Order number 2360922 | Edition 09/2022