10   Repairs
10   REPAIRS
10.1   REPAIR PERSONNEL
Repair work should be undertaken carefully by qualified and trained personnel. They should
be informed of specific hazards during their training.
The following hazards may arise during repair work:
– risk to health from inhaling solvent vapors,
– use of unsuitable tools and aids.
A skilled person must check to ensure that the device is in a reliable state after it is repaired.
A function test should be performed.
10.2   REPAIR NOTES
DANGER
Incorrect maintenance/repair!
Danger to life and equipment damage.
4 Only a WAGNER service center or a suitably trained person may carry out repairs and
replace parts.
4 Use only WAGNER original spare parts and accessories.
4 Only repair and replace parts that are listed in the spare parts chapter and that are
assigned to the device.
4 Before all work on the device and in the event of work interruptions:
4 Relieve the pressure from the spray gun, product hoses and all devices.
4 Secure the spray gun against actuation.
4 Switch off the energy and compressed air supply.
4 Disconnect the control unit from the mains.
4 Observe the operating and service manual for all work.
Before repair work
4 Flush and clean the system according to chapter Cleaning and flushing the device
[8 50].
After repair work
1. Carry out safety checks in accordance with chapter Safety Checks and Maintenance
Intervals [8 51].
2. Put the system into operation in accordance with chapter Start up [8 37] and check for
leaks in accordance with chapter Product Pressure Test [8 67].
3. Carry out functional check in accordance with chapter Function Test after Repair Work
[8 66].
4. Have the system checked for safe condition by a skilled person.
5. In accordance with DGUV regulation 100-500, chapters 2.29 and 2.36:
4 The liquid ejection devices should be checked by an expert (e.g., WAGNER service
technician) for their safe working conditions as required and at least every 12
months.
4 For shut down devices, the examination can be suspended until the next start-up.
54
Order number 2360922 | Edition 09/2022