Plc Side Setting (Gx Works3) - Mitsubishi Electric MELSERVO-J5 Series Sample Screen Manual

Servo amplifier
Hide thumbs Also See for MELSERVO-J5 Series:
Table of Contents

Advertisement

PLC side setting (GX Works3)

Default setting in the sample screen is as below.
When using the sample screens, change the settings in accordance with your system configuration.
(1) Select [Parameter] - [FX○○CPU] - [Module Parameter].
Set the IP address in [Own Node Settings] of [Basic Settings].
Parameter Setting Method
IP address setting
(2) Configure the settings of Ethernet Configuration in [External Device Configuration].
Go to [Module List] - [Ethernet Device (General)] to add the MELSOFT Connection Module to the Ethernet
configuration.
(3) Select [Parameter] - [Module Information] to add the motion module.
Go to [Required Settings] - [Station Type] to set the station type and network No.
Item
Station Type
1st PLC
Network No.
IP Address
Station Type
2nd PLC
Network No.
IP Address
Station Type
3rd PLC
Network No.
IP Address
(4) Go to [Basic Settings] - [Network Configuration Settings] to configure the network configuration settings.
For details, refer to the user's manual of the equipment used.
Item
IP Address
Set value
Parameter Editor
192.168.10.39
Set value
Master Station
1
192.168.3.249
Master Station
2
192.168.4.249
Master Station
3
192.168.5.249
103/128
Remarks
-
-
Remarks
-
-
-
-
-
-
-
-
-