Machine Diagnosis (Total Travel Distance) (B-15716)

1
2
Outline
This screen displays machine diagnosis information (total travel distance) and total travel distance failure
prediction diagnosed by the servo amplifier.
Description
1.
Displays motor total travel distance and failure prediction motor total travel distance.
2.
Displays the status of total travel distance failure prediction.
Failure prediction motor total travel distance is not displayed when Servo motor total travel distance failure
prediction warning selection (*MFP) is disabled.
Remarks
・ For the settings of total travel distance failure prediction (*MFP, FPMT and TMO), perform the settings with
MR Configurator2.
・ Failure prediction motor total travel distance can be displayed in maximum 10 digits.