Menu item
Relay output
Accept
Cancel
Operating
instructions
92
Selection/Values
Dxx / .../Ry
...
...
...
No relay output

5.6.3 Alarm output to display

When an alarm event occurs, a window with a text message appears.
figure 5-10 Example of an alarm message on the display
1 Alarm no. Axx and date and time of the alarm event
2
User-defined designation
3
Sensor number and model name of the sensor that triggered the
alarm event
4
Series number and name of the sensor that triggered the alarm
event
5
Description of the event with specification of the limiting value:
"<" = Undercut
">" = Exceeded
If there are several alarm messages indicated on the display, you can scroll
through the messages with < >. This can be recognized from the page
Explanations
Opens a list with all relay outputs where
the Alarm contact is set.
Dxx: number of the output module
.../Ry: relay output channel
Here you can select a relay output. When
the alarm event occurs, it carries out the
specified action (Open or Close). For
details, see section 5.6.3 A
.
TO DISPLAY
The settings are taken over in the setting
table by pressing <OK>. The display
switches to the next higher level.
The display switches to the next higher
level without storing the new settings.