Ethernet Connection (If Available); Controller Features - Leuze electronic LBK SBV Original Operating Instructions

Safe radar system
Table of Contents

Advertisement

9  Technical references
MRT**
Safe state when a fault occurs
Note*: the systematic capability is guaranteed only if the user uses the product according to the instructions
of this manual and uses the product in the appropriate environment.
Note**: the MRT considered is the Technical Mean Repair Time, i.e. it takes in consideration availability of
skilled personnel, adequate tools and spare parts. Considering the type of device, the MRT corresponds to
the time necessary for the device replacement.
9.1.3

Ethernet connection (if available)

Default IP address
Default TCP port
Default netmask
Default gateway
9.1.4

Controller features

Outputs
OSSD characteristic
Safety outputs
Inputs
Fieldbus interface (if available)
Power supply
Consumption
Assembly
Weight
Degree of protection
Terminals
Impact test
Shock/Bump
Vibration
Pollution degree
Outdoor use
Operating temperature
Storage temperature
Note*: the unit shall be supplied by an isolated power source which fulfils the requirements of:
Leuze electronic GmbH + Co. KG
< 10 min
At least one OSSD is in OFF-state. Stop message sent on fieldbus (if available) or
communication interrupted
192.168.0.20
80
255.255.255.0
192.168.0.1
Configurable as follows:
4 Output Signal Switching Devices (OSSDs) (used as single channels)
l
2 dual channel safety outputs
l
1 dual channel safety output and 2 Output Signal Switching Devices (OSSDs)
l
Maximum resistive load: 100 K Ω
l
Minimum resistive load: 70 Ω
l
Maximum capacitive load: 1000 nF
l
Minimum capacitive load: 10 nF
l
High-side outputs (with extended protection function)
Maximum current: 0.4 A
l
Maximum power: 12 W
l
The OSSDs provide what follows:
ON-state: from Uv-1V to Uv (Uv = 24V +/- 4V)
l
OFF-state: from 0 V to 2.5 V r.m.s.
l
2 dual channel type 3 digital inputs with common GND
See Voltage and current limits for digital inputs on page 97.
Ethernet based interface with different standard Fieldbus (e.g. PROFIsafe)
24 V DC (20–28 V DC) *
Maximum current: 1 A
Max. 5 W
On DIN rail
with cover: 170 g (6 oz)
IP20
2
Section: 1 mm
(16 AWG) max.
Maximum current: 4 A with 1 mm
0.5 J, 0.25 kg ball from a 20 cm height
10 g, 1000 times for X, Y, and Z directions (IEC 60068-2-27)
10-55 Hz double-amplitude of 0.7 mm (0.3 in), 20 sweeps in the X, Y and Z directions (IEC
60068-2-6)
2
No
From -30 to +60 °C (from -22 to +140 °F)
From -40 to +80 °C (from -40 to +176 °F)
Sensor LBK SBV
2
cables (16 AWG)
93