8  Maintenance and troubleshooting
LEVEL 3 / LEVEL 4 / LEVEL 5 The events are logged:
l
in a single field at controller level and the additional information are: detection field, detection
o
distance (in mm) and detection angle (in °) in access, and detection field at exit;
o
at sensor level and the additional information read by the sensor are: detection distance (in mm)
and detection angle (in °) in access, and detection field at exit.
Format:
CONTROLLER #k Detection access (field #n, distance mm/azimuth°)
SENSOR #k Detection access (distance mm/azimuth°)
CONTROLLER Detection exit (field #n)
SENSOR #k Detection exit
8.3
INFO events
8.3.1

System Boot

Every time the system is powered up, the event is logged reporting the incremental count of the boot from
the beginning of the life of the device.
Format: System Boot #n
Example:
0 2020/11/18 16:47:25 [INFO] CONTROLLER SYSTEM BOOT #60
8.3.2

System configuration

Every time the system is configured, the event is logged reporting the incremental count of the configuration
from the beginning of the life of the device.
Format: System configuration #3
Example:
20 2020/11/18 16:47:25 [INFO] CONTROLLER System configuration #3
8.3.3

Factory reset

Every time a factory reset is required, the event is logged.
Format: Factory reset
Example:
20 2020/11/18 16:47:25 [INFO] CONTROLLER Factory reset
8.3.4

Stop signal

If configured, every change of the Stop Signal is logged as ACTIVATION or DEACTIVATION.
Format: Stop signal ACTIVATION/DEACTIVATION
Example:
20 2020/11/18 16:47:25 [INFO] CONTROLLER Stop signal ACTIVATION