9  Technical references
9.5

Digital input signals

9.5.1

Stop signal

Part
Detection signal
1
Detection signal
2
Stop signal CH1
Stop signal CH2
Diff
Dt
9.5.2

Muting (with/without pulse)

Without pulse
Leuze electronic GmbH + Co. KG
Both deactivate on the falling edge of, at least, one of the two input channels of the
input signal. They remain in OFF-state as long as one of the two input channels
remains to the low logic status (0).
Interchangeable channel. As soon as one channel goes to the low logic level (0),
Detection signal 1 and Detection signal 2 are set to OFF-state.
Less than 50 ms. If the value is greater than 50 ms, the diagnostic alarm starts and the
system deactivates the safety outputs.
Activation delay. Less than 5 ms.