4  Get to know LBK SBV System
4.6

MODBUS communication

4.6.1

MODBUS support

The MODBUS communication uses the Ethernet port (MODBUS TCP) and consequently is only available
for LBK ISC BUS PS and LBK ISC-02 controllers.
4.6.2

MODBUS communication enabling

In the LBK Designer application, click on Settings > MODBUS Parameters > ON to enable the feature.
Within the Ethernet network, the controller acts like a server. The client must send requests to the IP
address of the server on the MODBUS listening port (default port is 502).
To show and change the address and the port, click on Settings > Network Parameters and Settings >
MODBUS Parameters.
4.6.3

Data exchanged through MODBUS

The following table details the data exchanged through the MODBUS communication:
Data type
Unsafe
Unsafe
Unsafe
Unsafe
Leuze electronic GmbH + Co. KG
SYSTEM STATUS DATA
LBK ISC BUS PS or LBK ISC-02 controller:
internal status
l
status of each of the four outputs
l
status of each of the two inputs
l
LBK SBV-01 sensor:
status of each detection field (target detected or not) or error
l
status
muting status
l
DYNAMIC CONFIGURATION STATUS
ID of the dynamic configuration currently active
l
signature (CRC32) of the dynamic configuration ID currently
l
active
TARGET DATA
Current distance and angle of the targets detected by each
l
sensor. For each detection field of each sensor, only the
closest target to the sensor is considered.
DIAGNOSTIC DATA
LBK ISC BUS PS or LBK ISC-02 controller:
internal status with an extended description of the error
l
condition
LBK SBV-01 sensor:
internal status with an extended description of the error
l
condition
Description
Sensor LBK SBV
Communication
direction
from the controller
from the controller
from the controller
from the controller